Stationary X-Ray Machine KSX-A100
Exposure Voltage 50 kV ~ 90 kV
Exposure Current Small focus: 25 mA
Big focus: (50, 75, 100 and 125) mA
Max. Output Voltage 90 kV
Max. Output Current 100 mA
Hospital bed KHB-A211
Back-rest angle 0° - 80° (±5°)
Knee-rest angle 0° - 40° (±5°)
Construction Electrostatic powder coated S.S. tube frame and head and foot board
Load capacity 250 Kgs
Diathermy Plate KDTP-A200
Conductive area 240 cm2
Type Unipolar
Dimension 240 mm x 140 mm
Ultrasound System with Trolley KUS-A100
Display size 15-inch LCD screen
Display depth 250 mm
Ultrasound modes B, B+B, B+M, M, 4B
TGC Total gain, 8 segment TGC
Multipurpose Operating Table KOT-B101
Length 2050 ± 50 mm
Width 480 ± 50 mm
Adjustable height (Min to Max) (750 to 950 ) ± 50 mm
Trendelenburg ≥ 20 °
Blood bank refrigerator KBR-A100
Available Options
IIIIIIIVVVI
Storage Capacity
25 bags (450 ml each)50 bags (450 ml each)100 bags (450 ml each)200 bags (450 ml each)300 bags (450 ml each)600 bags (450 ml each)
Internal Dimensions
350 x 370 x 520 mm543 x 516 x 595 mm543 x 516 x 797 mm543 x 516 x 1391 mm685 x 690 x 1350 mm690 x 1370 x 1350 mm
External Dimensions
655 x 450 x 765 mm594 x 600 x 1230 mm594 x 600 x 1230 mm594 x 600 x 2000 mm820 x 765 x 2000 mm820 x 1450 x 2000 mm
Throughput  
Mobile C-Arm X-ray KCX-A100
X-Ray Generator Frequency 40 kHz
Power Capacity 3.5 kW
Tube Current X-ray : 20 mA - 63 mA
Fluoroscopy : 8 mA
Tube Voltage 40 kV ~ 110 kV
Exposure Factor 1 ~ 125 mAs
Holter Monitor KHM-A100
Display OLED 160 x 128 dot matrix display
Storage Built-in TF card storage for up to 2 GB
Standard Sensitivity 10 mm/mV ± 5%
Sensitivity Shift ≤ ± 10%
Hospital bed KHB-A301
Height adjustability 180 mm - 600 mm
Back-rest angle 0° - 80° (±5°)
Knee-rest angle 0° - 40° (±5°)
Construction Electrostatic powder coated S.S. tube frame with ABS head and foot board
Surgical Diathermy Machine KSD-A100
Power Consumption 350 W
Operating Frequency 330 kHz ─ 460 kHz
Modes 6 Monopolar modes
2 Bipolar modes
Monopolar Cut : Pure Cut 1 W ─ 350 W at 500 Ω load impedance
Hospital bed KHB-A303
Height adjustability 450 mm - 700 mm
Back-rest angle 0° - 80° (±5°)
Knee-rest angle 0° - 40° (±5°)
Construction Electrostatic powder coated S.S. tube frame with ABS head and foot board
Infusion Pump KIP–A100
Channel Single channel infusion
Volume (VTBI) 1 ml ~ 9999.9 ml ( 0.1 ml increment)
Accuracy Flow rate: ≤ ± 3 %
Mechanical: ≤ ± 2 %
KVO Rate 1 ml/h (1 ml/h ~ 300 ml/h)
3 ml/h (greater than 300 ml/h)
Cassette printer KPS-A100
Speed ≥ 800 cassettes per hour
Method Ribbon thermal transfer mode
Print Resolution 400 dpi
Print medium type 35 mm wide thermal transfer ribbon
Vital Sign Monitor KPM-A100
Vital Parameters
Type AType BType C
4 Parameters (NIBP,SpO2, PR, Temp)3 Parameters (SpO2, PR, Temp)3 Parameters (NIBP, SpO2, PR)
Display 240 x 320 dot matrix colour TFT
NIBP Measurement range Adult: 30-255 mmHg
Paediatric: 30-160 mmHg 
NIBP Mode Auto, Manual, STAT
Mammography system KBS-A101
Generator Type High frequency inverter 40 kHz
Radiographic Ratings Large focal point, 20-35 kV/10-510 mAs
Small focal point, 20-35 kV/ 10-110 mAs
Focal Size Dual focus 0.5 mm
Input Power Single phase AC 220 V, 50-60 Hz