Kizlon Ltd
Kizlon Ltd
Kizlon Ltd
Kizlon Ltd

Medical Equipment Directory

Medical Diagnostic

Surgical

Critical Care

In-Vitro Diagnostic

General Aids

In-Patient Solutions

OR Solutions

Patient Transfer Solutions

Respiratory Aids

Mobility Aids

Daily Care

Medical Consumables

Medical Disposables

Diathermy Plate KDTP-A100
Conductive area 140 cm2
Type Unipolar
Use Adult
Dimension 210 mm x 105mm
Dialyzer Reprocessing Machine KDR-A200
Cycle time 8 minutes per cycle
Volume test range 0 mL to 150 mL ( ±3 % )
Maximum water inlet flow > 1600 mL/min
Water consumption 8 L
Hydraulic Stretcher KHS-A102
Trendelenburg 12 °
Variable height 630 to 950 mm
Anti-trendelenburg 12 °
Weight capacity 250 Kgs
Platelet Incubator KPI-A100
Temperature Range (Set point - 22°C) 22°C to 24°C
Capacity 1 agitator (5 shelves)
Internal dimensions 572 x 495 x 495 mm
Stroke speed 60 strokes/min
Hospital bed KHB-A307
Height adjustability 530 mm – 2000 mm
Back-rest angle 0° - 80°
Left Foot Raise 0° - 40°
Right foot raise 0° - 40°
Urea Breath Analyser KUBT-A100
No. of Channels 10
No. of Sample Analysis 5
Specificity 1
Sensitivity 0.95
Elastomeric Infusion Pump KEP-A100
Type Basic, CBI + PCA
Basal Flow rate 2 ml/hr, 3 ml/hr, 4 ml/hr, 5 ml/hr, 10 ml/hr
(default 2 ml/hr)
Capacity 60 ml / 100 ml / 150 ml / 200 ml / 275 ml
Pump shell Silicon pump with ABS closure
Hydraulic Stretcher KHS-B100
Trendelenburg 15 °
Variable height 630 to 950 mm
Anti-trendelenburg 15 °
Weight accuracy 0.02 or 0.05 kg
Diathermy Plate KDTP-A200
Conductive area 240 cm2
Type Unipolar
Dimension 240 mm x 140 mm
Hospital bed KHB-A101
Construction Electrostatic powder coated S.S. tube frame and ABS head and foot board
Load capacity 250 Kgs
Other components Urine hooks, I.V drip, heavy duty castors
Dimensions 2120 x 970 x 530 mm
Infrared Ear Thermometer KETH-C100
Temperature Measuring range 34 ⁰C ~ 44 ⁰C
Temperature Measuring accuracy ± 0.2 ⁰C
Measurement Time 1 s
Battery 2, AAA Battery
Veterinary Haematology Analyser KHA-C101
Type Fully automated 5-part differential system
Throughput 60 samples/hr
Principle of Operation Impedance, Colorimetry
Accuracy (CV %) WBC (109/L) : (0 - 100)
RBC (1012/L) : (0 - 1700)
HGB (g/L) : (0 - 250)
PLT(109/L) : (0 - 3000)
Hospital bed KHB-A305
Back-rest angle 0° - 80° (±5°)
Construction Electrostatic powder coated S.S. tube frame with ABS head and foot board
Load capacity 250 Kgs
Other components Urine hooks, I.V drip, heavy duty castors
Infusion Pump KIP–A100
Channel Single channel infusion
Volume (VTBI) 1 ml ~ 9999.9 ml ( 0.1 ml increment)
Accuracy Flow rate: ≤ ± 3 %
Mechanical: ≤ ± 2 %
KVO Rate 1 ml/h (1 ml/h ~ 300 ml/h)
3 ml/h (greater than 300 ml/h)
Automated External Defibrillator KED-A100
Waveform Biphasic
Energy Sequence 150 J, 200 J
Analysis Time 9 seconds
Audio Indications 20 distinct voice instructions
Oxygen Concentrator KOC-A102
Capacity 1 L
Flow Range 1 L/min – 5 L/min
Oxygen Concentration 90 % ± 3 %
Power Output 90 W